Bio-Layer Interferometry : ウィキペディア英語版
Bio-layer interferometry

Bio-layer interferometry (BLI) is a label-free technology for measuring biomolecular interactions within the interactome.〔Current Biosensor Technologies in Drug Discovery. Cooper, M. A. Drug Discovery World, 2006, 68-82〕〔Higher-throughput, label-free, real-time molecular interaction analysis. Rich, R. L.; Myszka, D. G. Analytical Biochemistry, 2007, 361, 1-6〕 It is an optical analytical technique that analyzes the interference pattern of white light reflected from two surfaces: a layer of immobilized protein on the biosensor tip, and an internal reference layer (Figure 1). Any change in the number of molecules bound to the biosensor tip causes a shift in the interference pattern that can be measured in real-time (Figures 1 and 2).
The binding between a ligand immobilized on the biosensor tip surface and an analyte in solution produces an increase in optical thickness at the biosensor tip, which results in a wavelength shift, Δλ (Figure 3), which is a direct measure of the change in thickness of the biological layer. Interactions are measured in real time, providing the ability to monitor binding specificity, rates of association and dissociation, or concentration, with precision and accuracy.
Only molecules binding to or dissociating from the biosensor can shift the interference pattern and generate a response profile. Unbound molecules, changes in the refractive index of the surrounding medium, or changes in flow rate do not affect the interference pattern. This is a unique characteristic of bio-layer interferometry and extends its capability to perform in crude samples used in applications for protein-protein interactions,〔Label-free Optical Biosensors in Drug Discovery. Fang, Y. Trends in Biopharmaceutical Industry, 2007, 3, 34-38〕 quantitation, affinity,〔Human Framework Adaptation of a Mouse Anti-Human IL-13 Antibody Fransson, J. and others. Journal of Molecular Biology, 2010, 398 (2), 214-231〕 and kinetics.〔Determining Kinetics and Affinities of Protein Interactions Using a Parallel Real-time Label-free Biosensor, the Octet. Abdiche, Y.N.; Malashock, D. S.; Pinkerton, A; Pons, J. Analytical Biochemistry, 2008, 377(2), 209-217〕
Bio-layer interferometry was pioneered by the founders of ForteBio, an instrument manufacturer with headquarters in Menlo Park California.